Administrator Programming

IP5131-SDL Settings

134

Strata CIX IP5000-series Telephone UG 07/09

IP5131-SDL Settings

This section contains instructions to configure the IP5131-SDL telephone. All
instructions found in this section pertain to the items found in the IP Configurations
screen of the IP5131-SDL telephone.

Configurations

Press

Hold

+

3

+

6

+

9

(simultaneously) to display the IP

Configurations main screen.

To access any of the screens that relate to an item on
the Configurations screen

Press the soft key that corresponds to the item. The
details pertaining to that item display.

Note

The following table explains each of the items
displayed on the Configurations screen.

I

TEM

I

NFORMATION

D

ISPLAY

Term Info

Displays the Software Version, the MAC address, the Regional Code
and xIPU address. You can press the EXIT soft key to go back to the IP
Configurations screen.

Note

This screen is for display only and you cannot make any
changes to the settings.

Network

Page 1:Displays or sets the DHCP, IP Address, Subnet, the default
gateway, station information and LIPU Address.

Page 2:Displays or sets node, IPU Mode, Primary IPU, Secondary IPU
and Port Settings.

Page 3:Displays or sets Auto Login Mode and Auto Login password.

Advance

Page 1:Displays or sets the Primary Name Server, the Secondary Name
Server, GRQ Port, RRQ Port, and AP Address

Page 2:Displays or sets the Admin address upper and lower bound, the
User ID and password, as well as the Dynamic Port Base.

Page 3:Displays or sets the VLAN Setting, PC Port type and PC Port
VLAN ID.

IP Configurations

Term Info

Network

Advance

Sound

Others

Key Repeat

Net Diag

Factory

Initialize

Reset

Config