Getting Started—Example Sessions

1-18

Introduction and Installation

Object file:

6) Enter the name of the COFF file containing the object code with which the

device is to be programmed. Press

, and the following prompt appears:

Object base address: all

where

all is the default, meaning that the entire object code address range

is to be used.

7) Select the address range default of

all by pressing

.

The cursor returns to the display window command line.

8) Press

to start the programming process. A prompt appears, asking for

the name of a file in which programming errors are to be recorded.

Error file:

9) Enter a file name and press

.

10) A prompt appears, asking for the starting address in PC memory of the

data to be used in programming.

PC memory base address: all

11) Accept the default all by pressing

.

12) Programming begins, and the bottom line of the screen is replaced by a

status message informing you of the beginning address of the packet (180
bytes) currently being programmed. This line will be replaced by an error
message if an error should occur. Otherwise, when programming is com-
plete, the bottom line of the screen shows a prompt asking if another de-
vice is to be programmed using the same parameters.

Programming Complete, Program another device? (y/n)

Press

n and then

to terminate programming and return to the display

window command line. The device is now programmed and verified, as-
suming no error messages appeared.