Data port Command Interface User Guide

Status format:
<ProductType>
<Uptime>
<Software

Version>
Name>
ReleaseDate>
Configuration

Telephony:>
VideoTelephony:>

<Hardware :

Version>
SerialNumber>
MainBoard>
AdditionalBoard>
Configuration:

PRI>

TemperatureCelcius>
TemperatureFahrenheit>

---

Parameters:

• ProductType, the name of the product, e.g. Video Portal

• Uptime, the time the system is running since the last reboot in seconds

• Software

o

Version, the unique name of the software

o

Name,

o

ReleaseDate, the time and date of the build of this software

o

Configuration

• Telephony, the amount of supported voice channels

• VideoTelephony, the amount of supported video channels

• Hardware

o

Version, software ID

o

SerialNumber, software serial number

o

MainBoard, the ID of the main board

o

AdditionalBoard, indicates extra boards in the box

o

Configuration:

• PRI, the amount of PRIs in the target system

• BRI, the amount of BRIs in the target system

• TemperatureCelcius, temperature of the main board in Celcius

• TemperatureFahrenheit, temperature of the main board in Fahrenheit

Example of SystemUnit feedback:
*s SystemUnit:
ProductType: "TANDBERG Video Portal"
Uptime: 15123
Software:
Version: "R3.0Beta2 (TEST SW)"
Name: "test"
ReleaseDate: "2007-03-21, 17:54"
Configuration:
Telephony: 0
VideoTelephony: 0
Hardware:
Version: "EP 1.0"
SerialNumber: "43A00001"
MainBoard: ""
AdditionalBoard: ""