12 threshold setting (cont.) – Toshiba B-SX6T Series User Manual

Page 95

Advertising
background image

2.PRINTER SETUP

ENGLISH VERSION EO1-33056

2.12 Threshold Setting

E2-81

2.12 Threshold Setting

(Cont.)


















„

Storing a “No Media Level” Voltage

The following is how to set a “No media level” voltage that is used to
detect a paper end.
If a “NO PAPER” is displayed even if the media has not run out yet, this
voltage needs to be set again.

(1) Remove any media from the Black Mark Sensor/Feed Gap Sensor.

(2) A real-time voltages being detected by the Black Mark Sensor and

Feed Gap Sensor are displayed.







(3) Press and hold the

[RESTART] or [FEED] key for about 3 seconds.




(4) When storing a “no media level” voltage is completed, an asterisk

“*”is displayed on the right side of a voltage. Press the

[PAUSE] key.


(5) The message returns to “<5>SENSOR ADJ.”.




„

Manual Threshold Setting

Then, set the calculated threshold voltage in the Parameter Fine
Adjustment mode.

(1)

While “<5>SENSOR ADJ.” is displayed, press the

[FEED] or

[RESTART] key until “<3>ADJUST SET” is displayed.





(2)Press the

[PAUSE] key to enter the Parameter Fine Adjustment Mode.



Feed Gap Sensor

Black Mark Sensor

<3> ADJUST SET
FEED ADJ.+10.0mm

<3>ADJUST SET

<5>SENSOR ADJ.
[PE]R0.1VT4.8V*

<5>SENSOR ADJ.

<5>SENSOR ADJ.

[PE]R0.1V T4.8V

Advertising
This manual is related to the following products: