Cleaning, Disassembly – Taylor 390 User Manual

Page 14

Advertising
background image

10

Model 390

Operating Procedures

Cleaning

Step 1
Prepare two gallons (7.6 liters) of an approved
cleaning solution (example: Kay-5

r

). USE WARM

WATER AND FOLLOW THE MANUFACTURER’S
SPECIFICATIONS.

Step 2
Pour the two gallons (7.6 liters) of cleaning solution
into the hopper and allow it to flow into the freezing
cylinder.

Step 3
While the solution is flowing into the freezing cylinder,
brush clean the mix hopper, mix inlet hole, and mix
level sensing probes.

Step 4
Place the control switch in the “WASH” position. This
will cause the cleaning solution to be agitated.

Step 5
Place an empty mix pail beneath the door spout and
move the draw handle to the right. Draw off all of the
cleaning solution. When the solution stops flowing
from the door spout, move the draw handle to the left
and place the control switch in the “OFF” position.

Disassembly

BE SURE THE CONTROL SWITCH IS IN

THE “OFF” POSITION. Failure to do so may cause
injury from electrocution or hazardous moving parts.

Step 1
Remove

the

handscrews,

freezer

door,

baffle

assembly, beater assembly, scraper blades, and drive
shaft from the freezing cylinder. Take these parts to the
sink for cleaning.

Step 2
Remove the front drip tray and splash shield and take
them to the sink for cleaning.

DRAW VALVE

ICE BUSTER

TOP

BACK

FRONT OF MACHINE

Advertising