Parameter Description

Basic operation in all menus (when navigating the menus via the LCD display)

Use ARROW keys to select value or submenu
Use ENTER to enter menus or for confirmation, and to activate

Use EXIT to step to a higher level or to decline an operation

Values are marked with an “ * “ when they can be altered via the ARROW keys

Main Display

The Main Display indicates the position of the monitor (when set up) and the set volume for the monitor.
A “+” symbol indicates that this specific Master Unit has been set up to act as System Controller.

Bass Management †
Bass management is possible in:
- Standard Stereo with 1 Sub
- Standard Stereo with 2 Subs
- All surround modes

The Precision monitors utilize 2nd order Hi Pass filters to attenuate frequencies below the set crossover frequency.
The subwoofer utilises 4th order Low Pass filter to attenuate frequencies above the set crossover frequency.

Press ENTER to access the Select Mode

Off - Bass Management is not activated. Only the LFE channel is distributed to the Sub.

Available Crossover Frequencies:

Menu Name

Precision Filter

Sub 4th Order

Sub 2nd Order

LFE = Sub

X-Over 50 Hz

50Hz

50Hz

50Hz

No

X-Over 80 Hz

80Hz

80Hz

80Hz

No

Extension 50 Hz

Off

50Hz

50Hz

No

Extension 80 Hz

Off

80Hz

80Hz

No

THX Sim 80 Hz

80Hz

80Hz

Off

Yes

Small Cons 120 Hz †† 120Hz

120Hz

80Hz

Yes

† PC-iP
Via the iDP PC-iP

installer package (optional software for the advanced installer) an advanced Bass Management mode

is available. In this mode a greater number of frequencies can be chosen, and all filters (Precision HPF, Sub 4th order
and Sub 2nd order) can be controlled to suit demanding & critical setups.

†† Small Cons - Small Consumer (filter to mimic a small consumer speaker)