Bottom view, Dip-switch – Transition Networks SISTM10XX-162-LR User Manual

Page 9

Advertising
background image

4

set all configurations back to default setting

Bottom View

The bottom view of the switch is shown below:

DIP-switch

The switch provides the 9 DIP-switch for configuring the relay alarm operation mode and the master

ring operation mode. The default value of Dipswitch is

OFF.

DIP Switch No

Status

Description

OFF

Disable port 1 Alarm

1

ON

Enable port Alarm. If the port’s link fails, the fault

LED will light up

OFF

Disable port Alarm

2

ON

Enable port Alarm. If the port’s link fails, the fault

LED will light up

OFF

Disable port Alarm

3

ON

Enable port Alarm. If the port’s link fails, the fault

LED will light up

OFF

Disable port Alarm

4

ON

Enable port Alarm. If the port’s link fails, the fault

LED will light up

Grounding Screw

6-position terminal block

Primary power input terminals (2)

Contact relay output terminals (2)

Secondary power input