10 - Service Information:

The following procedures are based upon having access to the steamer on all four sides. If the steamer is installed between
other appliances and there is not enough room on the sides for access, the steamer must then be pulled out from its
position to gain proper access.

Care should be taken in moving the steamer so as not to stress or pull on the electrical and water connections.

10.1

Top Right Side Panel (Louvered) - Removal
P/N 123183

1. With a flat blade screw driver remove the two 10-32

screws on the lower edge and one screw on the top
edge of the panel. The panel is held to the steamer
by two spring-like clips at the rear and bottom edge.

2. Once the screws are removed SLIDE the panel

towards the front with a lifting motion. Do not attempt
to PRY the panel. Once the panel is free of the rear
and lower clips, it may be lifted off.

ASSEMBLY TIP: When replacing the panel, press the
rear edge inward so that both clips will be retained by the
back flange. Make sure that the holes in the panel are in
alignment with the tapped holes in the steamer so that
the replacement of the two 10-32 screws will be easy and
not damage the screws.

10.2

Steamer Table Panels
Front P/N 125898
Rear P/N 096722
Left/Right Side P/N 125899

1. To remove the steamer table lower panel, simply

raise the panel and swing out. There are no fasteners
on this panels and it is retained only by upper and
lower tracks.

2. To remove the front and side panels remove the

screw(s) holding the panel, then remove the panels.

3. The front and rear panels are unique and the two

side panels are identical and interchangeable.

10.3

Top/Left Side - Removal
P/N 123184

Under normal conditions, the top/left side cover should
never have to be removed as there are no operational
and/or replacement parts to be accessed. The single
exception is if the door has been reversed so that the
handle is on the LEFT and the Door Interlock Switch is
found to be defective and must be replaced. The door
switches for BOTH door positions are installed at the time
of manufacture, so there is no need to access the switch
if the door is to be reversed.

1. If the top/left side cover must be removed due to a

faulty door switch, remove the right side panel (as
above) first.

Then remove the top left panel in the same manner.

ASSEMBLY TIP: In replacing the top/left panel assembly,
make sure that the retaining clip is replaced and screwed
down tight.

10.4

Adjustable Legs
P/N 042505

1. Each leg is provided with a screw type support post.

These may be extended or retracted by turning them
with a wrench or ChannelLock. Make sure that all
four legs are in tight contact with the floor for proper
steamer support.

2. If damaged, these posts may be replaced by tapping

out (on opposite sides of the leg) the threaded fitting
which is friction held in each stainless steel leg. The
stainless leg and the threaded fitting are one
assembly.

NOTE: The following components and assemblies are to
be found in the lower table portion of the steamer.

10.5

Steam Generator Drain Valve
P/N 071234

1. Turn off power and allow steamer to drain

completely. Remove back cover panel and loosen
hose clamps.

2. Using a 7mm nutdriver, disconnect both ends of the

drain hose from the spray box and the steam
generator.

3. Unplug and disconnect the valve electrical wires.

Remove the 10-32 keps nuts holding the valve to the
plate. Remove the valve from the threaded studs.
Then remove the silicone hose from the valve.

4. Inspect the silicone hose for any damage or lime

buildup. Replace hose if required.