4.0 - Installation and Start-Up

WARNING

THE UNIT MUST BE INSTALLED BY PERSONNEL WHO ARE QUALIFIED TO WORK WITH ELECTRICITY
AND PLUMBING. IMPROPER INSTALLATION CAN CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO
THE EQUIPMENT. THE UNIT MUST BE INSTALLED IN ACCORDANCE WITH APPLICABLE CODES.

CAUTION

DO NOT INSTALL THE UNIT WITH THE RIGHT SIDE VENTS BLOCKED OR WITHIN 30 CENTIMETERS
OF A HEAT SOURCE (SUCH AS A BRAISING PAN, DEEP FRYER, CHAR BROILER, OR KETTLE).

TO AVOID DRAINAGE PROBLEMS, LEVEL THE UNIT FRONT TO BACK.

4.1

Electrical Supply Connection

4.1.1

Access for Connection

Panel Removal
Open the lower front panel by removing the
screws from panel. Lift the panel, and swing its
bottom toward you. Set the panel aside.

4.1.2

Supply Voltage

The unit must be operated at the rated nameplate
voltage, plus or minus 10 percent.

4.1.3

Phase Selection

Refer to the schematic (Page 31) for wiring
information.

CAUTION

THE UNIT MUST HAVE A SEPARATE
EARTHING WIRE FOR SAFE OPERATION.

4.1.4

Terminal Block

The terminal block for incoming power is located
at the back of the control compartment.
The ground terminal is located in the wiring
compartment next to the terminal block. The unit
must have a separate ground wire for safe
operation
. The earthing wire must be of the
same size as the supply wire.

4.1.5

Supply wire

WARNING

TO AVOID DAMAGE OR PERSONAL INJURY,
FOLLOW THE ELECTRICAL SCHEMATIC
EXACTLY WHEN CONNECTING THE UNIT.

Determine the type of wire you need for the power
supply, find the operating voltage and phase on
the unit data plate, or use the table on the next
page. The “Electrical Supply Connection” label
inside the unit gives directions for proper
connection of the terminal block jumpers. The
knockout hole is sized for a 35 mm conduit fitting.