THROUGH THE WALL INSTALLATION

(RECOMMENDED INSTALLATION)

To vent the unit through the wall, connect the pipe adapter

to the exhaust motor adapter. If the exhaust adapter is at

least 18-inches above ground level, a straight section of

pellet vent pipe can be used through the wall.
Your Forester dealer should be able to provide you with

a kit that will handle most of this installation, which will

include a wall thimble that will allow the proper clearance

through a combustible wall. Once outside the structure, a

3-inch clearance should be maintained from the outside

wall and a clean out tee should be placed on the pipe with

a 90-degree turn away from the house. At this point, a

3-foot (minimum) section of pipe should be added with a

horizontal cap, which would complete the installation (see

FIGURE 6).
A support bracket should be placed just below the

termination cap or one every 4-feet to make the system

more stable. If you live in an area that has heavy snowfall,

it is recommended that the installation be taller than 3-feet

to get above the snowdrift line. This same installation

can be used if your stove is below ground level by simply

adding the clean-out section and vertical pipe inside until

ground level is reached. With this installation you have to

be aware of the snowdrift line, dead grass, and leaves. We

recommend a 3-foot minimum vertical rise on the inside or

outside of the house.

The “through the wall” installation is the least expensive and simplest installation. Never terminate the end vent under a

deck, in an alcove, under a window, or between two windows. We recommend Simpson Dura-Vent

®

or Metal-Fab

®

kits.

THROUGH THE ROOF/CEILING INSTALLATION

When venting the stove through the ceiling, the pipe is connected the same as through the wall, except the clean-out

tee is always on the inside of the house, and a 3-inch adapter is added before the clean-out tee.
You must use the proper ceiling support flanges and roof flashing (supplied by the pipe manufacturer; follow the pipe

manufacturer’s directions). It is important to note that if your vertical run of pipe is more than 15-feet, the pellet vent pipe

size should be increased to 4-inches in diameter.
Do not exceed more than 4-feet of pipe on a horizontal run and use as few elbows as possible. If an offset is required,

it is better to install 45-degree elbows rather than 90-degree elbows.

Installation

FIGURE 6

TYPICAL THROUGH THE WALL INSTALLATION