Installation, Iinspection – UltraViolet Devices Hygeaire Air Disinfection User Manual

Page 5

Advertising
background image

5

INSTALLATION

L

OCATION

The

Hygeaire

®

fixture is recommended for use in rooms with good ventilation, with a ceiling height of 9 feet or

more and where occupants remain for prolonged periods.

Access to the room does not need to be controlled while the fixture is operating.

The louver panels of the

Hygeaire

®

fixtures protect room occupants from ultraviolet exposure, by directing

ultraviolet radiation into the upper areas of the room.

Any plans for the installation of the

Hygeaire

®

fixtures, should take into account the reflectance of the ceiling.

Some finishes may have reflectances that are objectionably high, making exposure of more than a few hours
unsafe. If any help is needed in determining the reflectance of a surface, please contact the Factory.

Ultraviolet energy, produced by the germicidal lamp(s), can fade some colors and/or alter the surface of some
materials especially those directly irradiated by the lamp(s). If any help is needed in determining the ultraviolet
resistance of any material, please contact the Factory.

The

Hygeaire

®

LIND 24-EVO fixture is designed to mount horizontally on a vertical surface, or wall,

approximately 6 ½ to 7 feet above the floor.

The

Hygeaire

®

LIND 24-EVO-2PM fixture includes pendant hardware to suspend fixture from the ceiling.

Standard stem pipe length is 18 inches. Other lengths are available, contact the Factory with requirements.

IINSPECTION

Remove the

Hygeaire

®

fixture from its shipping carton. Inspect the fixture, and wire leads for damage. Do not oper-

ate if there is any damage to the fixture, and/or wire leads. Lamp(s) are packed separately, to ensure maximum protec-
tion to the lamp(s). Keep the lamp(s) aside until ready for installation. When installing lamp(s) into the fixture, exercise
care not to touch the lamp's glass. Oils deposited, from fingers, on the glass could effect ultraviolet transmission.
The

Hygeaire

®

Model LIND 24-EVO fixture includes:

1 - Model LIND 24-EVO single lamp fixture with 6 inch lead wires

1 - Germicidal Ultraviolet Lamp

1 - Operating Instructions

The

Hygeaire

®

Model LIND 24-EVO-2PM fixture includes:

1 - Model LIND 24-EVO-2PM dual lamp fixture with 4 ½ foot lead wires

1 - Pendant Mounting Kit, consisting of:

1 - #19 Crossbar

1 - #11 Canopy

2 - 3/8" IP Stems 18 inches long

2 - #14 3/8" IP Slip Rings

6 - #22 3/8" IP Locknuts

2 - Germicidal Ultraviolet Lamps

1 - Operating Instructions

Advertising