Troubleshooting, Technical specifications – UltraViolet Devices Hygeaire Air Disinfection User Manual

Page 9

Advertising
background image

9

TROUBLESHOOTING

CAUTION: Always disconnect power to the fixture, before performing any service.

IMPORTANT: This fixture is to be serviced ONLY by qualified, and appropriately licensed, personnel.

Table 1 - Troubleshooting

!

Use personal protection equipment, such as gloves; long sleeves with no gaps between cuffs
and gloves, and ultraviolet resistant face shield, if troubleshooting

Hygeaire

®

.

Problem Possible

Cause

Corrective

Action

No electrical power…

Verify that the purifier is connected to a live power source.

Power connections, to fixture,

Verify power connections to fixture are fully engaged.

loose or disconnected…

Lamp(s) not installed…

Install lamp(s).

Germicidal lamp not

Confirm connection of lamp and lamp holder, make sure

properly seated…

connection is tight and lamp holder is making full contact
with lamp.

Germicidal lamp faulty…

Swap suspect lamp, with lamp known to be good. If
suspect lamp does not operate, replace lamp.

Ballast not functioning…

Locate ballast and replace.

Interlock Switch open…

Confirm louver panel is closed and secured.

Interlock Switch faulty…

Replace Interlock Switch.

Fixture not operating.

Germicidal lamp
not operating.

TECHNICAL SPECIFICATIONS

Table 2 Technical Specifications

MODEL

LIND 24-EVO

LIND 24-EVO-2PM

Length:

24"

24"

Dimensions:

Width:

4

1

/

2

"

9"

Height:

7-

7

/

8

"

7-

7

/

8

"

Volts:c

120v

220-240v

120v

220-240v

Electrical:

Amps (Max):

.42A

.23A

.83A

.45A

Frequency:

50/60Hz

50/60Hz

50/60Hz

50/60Hz

Total Ultraviolet Output:c

8.5 Watts

17 Watts

c

Ultraviolet output at 254 nm at 100 hours and 80° F (approximate).

d

120v 50/60Hz and 220-240v 50/60Hz units are standard - specify when ordering. Consult factory
with other specific power requirements.