United States Stove Company DV20 User Manual

Page 12

Advertising
background image

12

USSC

Diagram Nº 11. Correct Flame Pattern

Diagram Nº 12. Incorrect Flame Pattern

Diagram Nº 10. Correct Flame Pattern

Optional Blower - DVBS (DV12) and DVBL (DV20)

Wiring Diagram

CAUTION: Label all wires prior to

disconnection when servicing

controls. Wiring errors can cause

improper and dangerous operation.

Verify proper operation after

servicing.

Permanently lubricated bearing

system.

WARNING: ELECTRICAL
GROUNDING INSTRUCTIONS.
This appliance is equipped with a
three-prong (grounding) plug for your
protection against shock hazard and
should be plugged directly into a
properly grounded three-prong re-
ceptacle. Do not cut or remove the
grounding prong from this plug.

Wiring Schematic

If any of the original wire as supplied
with the appliance must be replaced,
it must be replaced with 600 volt - 150
degree C. wire or its equivalent.

Advertising
This manual is related to the following products: