United States Stove Company DV20 User Manual

Page 2

Advertising
background image

2

USSC

GAS SPECIFICATIONS

MODEL

FUEL

MAXIMUM INPUT

DV12

Natural

10,000 BTU/hr

Liquid Propane

10,000 BTU/hr

DV20

Natural

18,000 BTU/hr

Liquid Propane

18,000 BTU/hr

MANIFOLD PRESSURE

Natural Gas

- DV12 - 5.8” w.c.

DV20 - 5.2” w.c.

Propane / LP Gas - DV12 - 10.8” w.c.

DV20 - 10.6” w.c.

GAS INLET

3/8” NPT

SUPPLY

MIN. PRESSURE

MAX. PRESSURE

Natural

7” W.C.P.

10.5” W.C.P.

Propane / LP

11.0” W.C.P.

13.0” W.C.P.

USE ONLY THE TYPE GAS SPECIFIED ON THE RATING PLATE

INTRODUCTION

Your LONGVIE heater is especially designed to provide maximum comfort to you and your home. Its large solid injected
aluminum front grill assures the optimum use of the generated heat in the ambient, maintains normal temperatures behind
the heater to avoid sticking of particles, which would soil the wall. You can feel safe with absolute security guaranteed by:

Its thermocouple security valve, which cuts the supply of gas in the event of the heater extinguishing due to strong air
currents, momentary interruption of the supply of gas.

Its gas pressure regulator assures an optimum operational; function, avoiding peak pressures in the gas supply
affecting normal combustion.

Its gas tight combustion chamber, totally enameled, avoids gases which are caused by combustion, to contaminate
the air and ensures a useful , long lasting working life.

Long lasting working life...Guaranteed by the quality of its components and high technology applied in the process of
fabrication, and especially by the traditional vocation of LONGVIE to produce durable products for your maximum comfort
and satisfaction.

LOCAL CODES

Install and use the heater with care. The installation must conform with local codes or in the absence
of local codes, use the latest edition of The National Fuel Gas Code ANSI Z223.1/NFPA 54*. Natural
Gas and Propane Installation Code, CSA B149.1.

A manufactured home (USA only) or mobile home OEM installation must conform with the Manufac-
tured Home Construction and Safety Standard, Title 24 CFR, Part 3280
, or, when such a standard is
not applicable, the Standard for Manufactured Home Installation, ANSI Z225.1, or Standard for Gas
Equipped recreational Vehicles and Mobile Housing, CSA Z240.4.

*Available from:

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018