U-Line CO29FF User Manual

Page 10

Advertising
background image

10

CO29FF

Condenser Cleaning

Interval - Every Three Months
To maintain operational efficiency, keep the front grille
free of dust and lint, and clean the condenser every three
months. Depending on environmental conditions, more
or less frequent cleaning may be necessary.

WARNING

Disconnect electric power to the unit before
cleaning the condenser.

WARNING

DO NOT touch the condenser fins. The condenser
fins are SHARP and can be easily damaged.

IMPORTANT

IMPORTANT

DO NOT use any type of cleaner on the condenser
unit.

1. Disconnect power to the unit.

Figure 7

2. Remove the control knob (Figure 7, 1) by pulling it

straight out, away from grille.

3. Remove two screws from grille (Figure 7, 2) and save.

4. Remove grille and grille cap from unit.

Figure 8

5. Clean the condenser coil (Figure 8, 1) using a using a

soft brush with a “combing” action or vacuum cleaner.
Do not touch the condenser coil.

Figure 9

6. Make sure grille cap is behind grille in slots provided in

grille (Figure 9, 1) before attaching grille to unit, and
secure but do not overtighten both grille screws
(Figure 9, 2).

7. Reinstall the control knob (Figure 7, 1).

8. Reconnect power to the unit.

Ice Maker Maintenance

Inlet Screen

Interval - Every Twelve Months
The solenoid valve inlet screen must be cleaned at least
once each year as follows:

1. Shut off the water at the main supply valve.

2. Pull the unit out to access the back panel.

3. Disconnect electrical power to the unit.

Figure 10

4. Disconnect the hose connector (Figure 10, 1) from the

water solenoid valve (Figure 10, 2).

5. DO NOT remove the inlet screen from the water

solenoid valve. Use a tooth brush to gently clean any
sediment from the inlet screen.

6. Re-connect the water supply hose connector (Figure

10, 1) to the water solenoid valve (Figure 10, 2).
Tighten the connector securely.

7. Open the water main supply valve and check for

leakage at the water hose connection. Ensure that the
water supply line is not kinked.

8. Reconnect power to the unit before re-installing.

2

1

ULIN_0197_A

1

ULIN_0153_A

ULIN_0198_A

2

1

2

1

ULIN_0054_A

ULIN_016357_30099.fm Page 10 Monday, March 27, 2006 10:22 AM

Advertising