ADJUSTING ICE THICKNESS

The ice thickness control is set to
automatically maintain an ice
bridge of 0.16-0.32 cm (1/16-
1/8 inch) thick. A dimple in each
cube is normal (see Figure 28). If
an adjustment is needed, per-
form the following steps:

Do not touch electrical wires. Disconnect
power to the ice maker before making any ice
thickness adjustments.

1. Disconnect power from the unit.

2. Remove front access panel (2 screws).

3. Locate the ice thickness adjustment dial on the control board (see

Figure 29).

Figure 29

UL318A

DIAL IS FACTORY

SET TO +1

ICE THICKNESS

ADJUSTMENT

DIAL

0

1

2

3

4

5

-5

-4

-3

-2

-1

0

1

2

3

4

5

-5

-4

-3

-2

-1

!

WARNING

!

22

User’s Manual

ICE BRIDGE SHOULD BE

1/16 - 1/8 INCH THICK

A DIMPLE IN EACH

CUBE CELL IS NORMAL

UL250

Figure 28