VIEWSONIC PS500B User Manual

Page 21

Advertising
background image

PS500B/PS800B

13

Data-Line Surge Suppression

Telephone Line Surge
Protection

+/- 6KV Peak

(1.2

µ

S/50 Waveform)

10/100 Base-T Protection
Let Through Rating

<1%

(From 6KV/125A Normal Mode Surge)

Audible Alarm

Battery discharge at power failure

Beep every 4 seconds

Battery approaches final discharge

Beep every second

Overload

Continuous buzzer

UPS faulty

Continuous buzzer

Battery and Charger

Battery type: Maintenance-free sealed-lead acid. Recharge time 6 to 8 hours
typical from total discharge. (The UPS may be used immediately after
discharge but will provide shorter backup time
)

Battery Specifications

PS500B

PS800B

DC voltage

24V

24V

Type

12V

4.5AH

12V

5AH

Quantity

2

2

Recharge time

4 Hours

4 Hours

Advertising
This manual is related to the following products: