Unvented propane/lp gas log heater vanguard, Operating heater, Inspecting burners – Vanguard Managed Solutions VYS30PWA User Manual

Page 16: Continued, Pilot flame pattern, Burner primary air holes, Main burner

Advertising
background image

16

105190

UNVENTED PROPANE/LP GAS LOG HEATER

VANGUARD

ON
OFF
REMOTE

O

FF

PILO

T

O

N

L O

I H

OPERATING
HEATER

Continued

Figure 23 - Thermostat Hand-Held Remote Control Unit Selections (GHRCT Series only)

Figure 22 - Setting the Selector Switch, Control Knob, and Flame Adjustment Knob for
Remote Operation

Selector Switch in Remote Position
(Optional Remote Control)

Control Knob in
On Position

Flame Adjustment Knob

Figure 24 - Correct Pilot Flame Pattern

Pilot Burner

Thermocouple

Figure 25 - Incorrect Pilot Flame Pattern

Check pilot flame pattern and burner flame
patterns often.

PILOT FLAME PATTERN

Figure 24 shows a correct pilot flame pat-
tern. Figure 25 shows an incorrect pilot
flame pattern. The incorrect pilot flame is
not properly heating the thermocouple.
When the thermocouple cools, the heater
will shut down.

If pilot flame pattern is incorrect, as shown
in Figure 25

• turn heater off (see To Turn Off Gas to

Appliance, page 15)

• see Troubleshooting, pages 17 through 19

Pilot Burner

Thermocouple

INSPECTING
BURNERS

BURNER PRIMARY AIR HOLES

Air is drawn into the burner through the
holes in the fitting at the burner entrance.
These holes may become blocked with dust
or lint. Periodically inspect these holes for
any blockage and clean if needed. Blocked
air holes will create soot.

MAIN BURNER

Periodically inspect all burner flame holes
with the heater running. All slotted burner
flame holes should be open with yellow
flame present. All round burner flame holes
should be open with a small blue flame
present. Some burner flame holes may be-
come blocked by debris or rust, with no flame
present. If so, turn off heater and let cool.
Either remove blockage or replace burner.
Blocked burner flame holes will create soot.

IMPORTANT:

This remote control

has been specially engineered to
take an air temperature sample ev-
ery 5.5 minutes in the auto mode.
It will not respond immediately to
the temperature setting being
turned up or down.

IMPORTANT:

The hand-held re-

mote control unit must be near the
heater. Do not keep the hand-held
remote control unit too close to the
heater. The thermostat on the
hand-held remote control unit will
heat up too quickly and turn the
heater off.

3.

To turn the burner off, press the
AUTO/ON/OFF button until OFF
lights. The pilot will remain lit.

IMPORTANT:

To turn the pilot off,

manually turn the control knob on the
heater to the OFF position.

Increases Room
Temperature in
AUTO Mode

Decreases Room
Temperature in
AUTO Mode

Turns Burners
On or Off and
Allows You to
Choose the Auto
Setting

Shows Temperature Setting

The Log Heater will
Automatically Cycle
between Pilot and the
Heat Setting that has
been Selected

Advertising