Owner’s manual, Cleaning and maintenance – Vanguard Managed Solutions VYS30PWA User Manual

Page 21

Advertising
background image

21

105190

OWNER’S MANUAL

CLEANING AND
MAINTENANCE

WARNING: Turn off heater

and let cool before cleaning.

CAUTION: You must keep

control areas, burner, and circu-
lating air passageways of heater
clean. Inspect these areas of
heater before each use. Have
heater inspected yearly by a quali-
fied service person. Heater may
need more frequent cleaning due
to excessive lint from carpeting,
bedding material, pet hair, etc.

CLEANING BURNER
INJECTOR HOLDER AND
PILOT AIR INLET HOLE

The primary air inlet holes allow the proper
amount of air to mix with the gas. This
provides a clean burning flame. Keep these
holes clear of dust, dirt, and lint. Clean these
air inlet holes prior to each heating season.
Blocked air holes will create soot. We rec-
ommend that you clean the unit every 2,500
hours of operation or every three months.

We also recommend that you keep the burner
tube and pilot assembly clean and free of
dust and dirt. To clean these parts we recom-
mend using compressed air no greater than
30 PSI. Your local computer store, hard-
ware store, or home center may carry com-
pressed air in a can. You can use a vacuum
cleaner in the blow position. If using com-
pressed air in a can, please follow the direc-
tions on the can. If you don't follow direc-
tions on the can, you could damage the pilot
assembly.

1.

Shut off the unit, including the pilot.
Allow the unit to cool for at least thirty
minutes.

2.

Inspect burner, pilot, and primary air
inlet holes on injector holder for dust
and dirt (see Figure 26).

3.

Blow air through the ports/slots and
holes in the burner.

Figure 26 - Injector Holder On Outlet
Burner Tube

Burner
Tube

Injector Holder
(May Be Brass
or Aluminum
Depending on
Model)

Primary Air Inlet
Holes (Shape of
Holes May Vary
by Model)

Burner
Tube

Pilot
Assembly

Pilot Air
Inlet Hole

Ports/Slots

Figure 27 - Pilot Inlet Air Hole

4.

Check the injector holder located at the
end of the burner tube again. Remove
any large particles of dust, dirt, lint, or
pet hairs with a soft cloth or vacuum
cleaner nozzle.

5.

Blow air into the primary air holes on
the injector holder.

6.

In case any large clumps of dust have
now been pushed into the burner repeat
steps 3 and 4.

Clean the pilot assembly also. A yellow tip
on the pilot flame indicates dust and dirt in
the pilot assembly. There is a small pilot air
inlet hole about two inches from where the
pilot flame comes out of the pilot assembly
(see Figure 27). With the unit off, lightly
blow air through the air inlet hole. You may
blow through a drinking straw if compressed
air is not available.

LOGS

• If you remove logs for cleaning, refer to

Installing Logs, page 13, to properly re-
place logs.

• Replace log(s) if broken or chipped

(dime-sized or larger).

MAIN BURNER

Periodically inspect all burner flame holes
with the heater running. All slotted burner
flame holes should be open with yellow
flame present. All round burner flame holes
should be open with a small blue flame
present. Some burner flame holes may be-
come blocked by debris or rust, with no
flame present. If so, turn off heater and let
cool. Either remove blockage or replace
burner. Blocked burner flame holes will
create soot.

Advertising
This manual is related to the following products: