16. Gas Conversion

WARNINGS

: Procedures to adapt the boiler to the type of gas available must be

carried out by a competent and responsible person. Components
used to adapt it to the type of gas available must be genuine parts
only.







Procedures:

• Check that the gas

cock (30 on Section
4) fitted on the gas
supply pipe is turned
off and the appliance
is switched off at the
circuit breaker.

• Remove the front and

side panels of the
case (see the section
17.2 Annual
Maintenance –
Dismantelling the
External Panels).

• Take off the lid of the

sealed chamber.

• Remove the front

panel of the
combustion chamber.

A

A

7

Figure 16.1

• Loosen the screws A

and remove the
burner 7 (Figure
16.1).

• Carry out the

conversion for the

type of gas, replacing
the burner injectors
correctly.

• Re-assemble the

burner, the front panel
of the combustion
chamber and the lid
of the sealed
chamber.

• Extract the control

panel as explained in
the section 12.1 of
this manual.

• Loosen the screws D

and remove the
service panel (figure
16.2)

D

D

D

Figure 16.2

• Set correctly the dip-

switch "2" to the
correct position (Fig.
16.3) in accordance
with the following
table.

Gas supply

Position of
the switch 2

Natural gas

On

L.P.G. Off

ON

OFF

1

2

3

4

ON

OFF

1

2

3 4

Natural gas

L.P.G.

Figure 16.3

• Close the service

panel.

• Turn on the boiler.
• Calibrate the gas

valve according to the
instructions given in
section 15.4 of this
manual.

• Set the correct gas

pressure for central
heating output
required.

• Stick on the inside of

the left hand side
panel adjacent to the
data badge the self-
adhesive label
(included with the
conversion kit)
indicating the type of
gas, and the gas
pressures to which
the appliance has
been set.

• Reassemble the front

and side panels of the
case.


RIVA HEAT ONLY MANUAL – REV A

36

Advertising