Installation details continued – Vent-a-Hood SLH6-K User Manual

Page 4

Advertising
background image

Page 4

(Rev. 04/08)

L114A

Model

K250 (Top Vent - High)

Volts

Amps

RPM

CFM

[email protected]

Equivalent CFM

CFM

[email protected]

CFM

[email protected]

CFM

[email protected]

Minimum Round

Duct Size

Square

Inches

#

K250 (Top Vent - Low)

K250 (Back Vent - High)

K250 (Back Vent - Low)

115

115

115

115

3.2

3.2

3.2

3.2

1550

1200

1550

1200

240

170

220

175

360

255

330

265

225

170

215

170

215

160

195

160

200

155

180

145

7” (or equivalent)

7” (or equivalent)

7” (or equivalent)

7” (or equivalent)

38

38

38

38

All K-Series hoods have two halogen lights.
Because the Magic Lung

®

uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung

®

blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently

than other filtration systems. When comparing the Magic Lung

®

with other blower units made by other manufacturers, use the “Equivalent CFM”.

#

Wall Cutout for Horizontal Ducting

Viewed from Front

Bottom of

Cabinet

3⁄8"

3 ½"

5 1⁄8"

5 1⁄8"

6 ¼"

1 1⁄8"

Electrical

CL

Installation Details Continued

6) Remove the hood from its packaging and place on the floor or countertop in front of the cabinet where it will hang.

Warning: Do not operate hood without proper ground connection.

Warning: Make sure power is off and locked at the service disconnecting

means on the service panel during installation.

7) Determine whether the electrical wire will enter from the top or the back of the hood. Remove the electrical enclosure

cover (1 screw) and the top or back electrical enclosure knockout from the hood. Install an appropriate 1/2” UL listed
electrical wire clamp through the electrical knockout. Install electrical wiring from the electrical panel to the hood
location.

8) Insert the electrical wire through the electrical wire clamp allowing 3” - 4” of wire inside the enclosure for hookup.

Tighten the electrical wire clamp.

9) From inside the hood, using UL listed wire nuts, attach the “neutral” wire to the white lead, the “hot” wire to the black

lead, and the ground wire to the green lead inside the junction box. Replace the electrical cover previously removed in
Step 7.

10) FOR BACK VENTING APPLICATIONS ONLY. IF YOU ARE NOT BACK VENTING, PROCEED DIRECTLY TO STEP 12.

Note: Wall studs may interfere with back venting installations.
Additional framing may be required. It is necessary to cut a
duct access hole in the wall prior to installing the hood. Starting
2 1/8” above the bottom edge of the hood, cut a hole 3 1/2”
high x 10 1/4” wide (see diagram at right).

11) Install the duct from the outside of the home to the duct access

hole in the wall. Where possible, use duct tape to seal joints.

12) While aligning the duct and guiding the wires, position the

hood under the cabinet. The duct should connect together as
the hood is located in place. Note: Unless using the VP521
transition, the duct work must fit inside the exhaust collar. If
using the VP521, 7” round duct should be placed with the non-
crimped end on the outside of the collar of the VP521 exhaust
outlet. Using the four screws provided, attach the hood to the
bottom of the cabinet.

14) Refer to the Owner Maintenance Guide Operating Instructions for proper hood operation. Test all blower and light

functions to ensure they are operating properly.