Electrical connection (3-wire), Leg installation, Warning – Viking F20508 User Manual

Page 7

Advertising
background image

13

1

2

4

1

1

3

5

Attach line #1 (red) and line #2 (black)

leads to outside terminal. Attach neutral wire (white)

to center terminal on the terminal block.

Push supply cord toward terminal

block to relieve strain, reattach supply cord strain

relief bracket over supply cord.

1

2

6

Reattach access door.

12

2

1

1

Remove access door.

Electrical Connection (3-wire)

Use a 3-wire power supply cord kit rated for
60 amps – 125/250 volts with closed loop
terminals and marked for use with ranges.

DO NOT use a GFI circuit. Where local
codes do not permit grounding through
neutral, use a 4-wire power supply cord. The
cord or conduit must be secured to the
range with the strain relief bracket.

The electrical connection is made at the
terminal block, which is located behind the
access door on the back of the range.

3

2

1

2

Remove supply cord strain relief

bracket and three supply cord mounting screws

on terminal block.

WARNING

Electrical shock hazard.

To avoid risk or electrical

shock, personal injury or death;

grounding product to the frame

of the unit may or may not be permitted

through your local codes. If ground to the

frame is not permitted then a 4 conductor

power cord must be used.

WARNING

Electrical shock hazard.

To avoid risk of electrical shock,

personal injury or death; verify

your appliance has been

properly grounded in accordance with

local codes or in absence of codes, with

the National Electrical Code (NEC).

ANSI/NFPA 70-latest edition.

3

Feed supply cord up through hole in bottom

of range back.

Note: If you have a 4-wire connection, see following section for
4-wire connection instructions.