Vermont Castings FK28/2960 User Manual

Circulating fan kit, Installation instructions, Fk28-1

Advertising
background image

WARNING

Circulating Fan Kit

Installation Instructions

Model: FK28/2960

For use with
Pinnacle PDV20/SDVR Direct Vent,
Stardance/Pinnacle UVS27 Vent Free,
Jefferson Direct Vent, Jefferson Unvented
JUV Gas Heaters and Seville Woodburning
Stove

Read these instructions completely before
beginning installation.

The Fan Kit FK28/2960 attaches to the rear shroud
of the PDV20/SDVR Direct Vent heater, the UVS27
Unvented, Jefferson Direct Vent, Jefferson JUV
Unvented heaters and the Seville Woodburning Stove.
Installation for the PDV20 should be made after the fire-
box is set within the stove shell but before connection
to the gas supply. Installation for the UVS27 should be
made before the firebox is set within the shell. Installa-
tion for the Jefferson Direct Vent and JUV may be made
at any time during assembly. Installation for the Seville
should be made before the stove is removed from the
shipping pallet. Follow the procedure for the appropriate
firebox model.
The kit includes a snapstat sensor which turns the fan
on or off at approximately 109˚F. Be sure the heater is
cool before beginning the installation.
Fan Kit Contents:
• #10 x 1/2” Phillips screws, 6
• Star Washer

• Wire Tie

• Control Knob

• Retaining Nut

• Snapstat

• Snapstat Bracket

• Blower Assembly w/ Rheostat Control and Snapstat
• Silicone Tape

30000275 8/08 Rev. 6

This appliance is equipped with a three-prong

(grounded) plug for your protection against

shock hazard and should be plugged into a

properly grounded three-prong receptacle. Do

not cut or remove the grounding prong from this

plug.

PDV20/SDVR Installation Procedure
– for Pinnacle Direct Vent

1. Attach the Snapstat to the Bracket using two #10 x

1/2” phillips screws as shown in Figure 1.

2. Locate and remove the 1/4-20 x 3/8” hex head bolt

installed in the hole in the right rear ledge of the fire-
box. (A, Fig. 1) Use that bolt to secure the Snapstat
Bracket to the firebox. The mounting hole is slotted to
let you adjust the bracket so that the snapstat head
makes contact with the firebox surface. (Fig. 1)

3. Attach the Fan to the firebox by engaging the upper

flange of the fan skirt under the lower edge of the
Shroud and secure the skirt with the four #10 x 1/2”
Hex Hd Cap screws and one star washer provided.
(Fig. 2)

FK28-1

Fig. 1 Snapstat assembly and installation. (PDV20 shown)

1/4-20 x 3/8”

Hex Bolt

1/2” Sheet

Metal Screws

Snapstat

Bracket

A

Fig. 2 The upper flange of the fan skirt should be located
behind the lower edge of the shroud. (PDV20 shown)

Upper

Flange

Rheostat

Control

Sheet Metal

Screws (4)

Fig. 3 Correct position of fan skirt installation. (PDV20 shown)

FK28-3

Advertising