Cleaning and maintenance – Vanguard VI33PRA User Manual

Page 19

Advertising
background image

110150-01B

For more information, visit www.desatech.com

For more information, visit www.desatech.com

19

19

CLEANING AND MAINTENANCE

Cleaning Burner Injector Holder And Pilot Air Inlet Hole

Logs

Burner Primary Air Holes

Main Burner

CLEANING AND
MAINTENANCE

WARNING: Turn off heater and let cool before

cleaning.

CAUTION: You must keep control areas, burner,

and circulating air passageways of heater clean. In-
spect these areas of heater before each use. Have
heater inspected yearly by a qualified service person.
Heater may need more frequent cleaning due to exces-
sive lint from carpeting, pet hair, bedding material, etc.

LOGS

• If you remove logs for cleaning, refer to Installing Logs, pages

13 and 14, to properly replace logs.

• Replace log(s) if broken or chipped (dime-sized or larger).

BURNER PRIMARY AIR HOLES

Air is drawn into the burner through the holes in the fitting at the
burner entrance. These holes may become blocked with dust or lint.
Periodically inspect these holes for any blockage and clean if
needed. Blocked air holes will create soot.

MAIN BURNER

Periodically inspect all burner flame holes with the heater running. All
slotted burner flame holes should be open with yellow flame present.
All round burner flame holes should be open with a small blue flame
present. Some burner flame holes may become blocked by debris or
rust, with no flame present. If so, turn off heater and let cool. Remove
blockage, blocked burner flame holes will create soot.

CLEANING BURNER INJECTOR HOLDER
AND PILOT AIR INLET HOLE

The primary air inlet holes allow the proper amount of air to mix with
the gas. This provides a clean burning flame. Keep these holes clear
of dust, dirt, lint, and pet hair. Clean these air inlet holes prior to each
heating season. Blocked air holes will create soot. We recommend
that you clean the unit every three months during operation and have
heater inspected yearly by a qualified service person.

We also recommend that you keep the burner tube and pilot
assembly clean and free of dust and dirt. To clean these parts we
recommend using compressed air no greater than 30 PSI. Your local
computer store, hardware store, or home center may carry com-
pressed air in a can. You can use a vacuum cleaner in the blow
position. If using compressed air in a can, please follow the direc-
tions on the can. If you don't follow directions on the can, you could
damage the pilot assembly.

1.

Shut off the unit, including the pilot. Allow the unit to cool for
at least thirty minutes.

2.

Inspect burner, pilot, and primary air inlet holes on injector
holder for dust and dirt (see Figure 40).

3.

Blow air through the ports/slots and holes in the burner.

4.

Check the injector holder located at the end of the burner tube
again. Remove any large particles of dust, dirt, lint, or pet hair
with a soft cloth or vacuum cleaner nozzle.

5.

Blow air into the primary air holes on the injector holder.

6.

In case any large clumps of dust have now been pushed into
the burner repeat steps 3 and 4.

Clean the pilot assembly also. A yellow tip on the pilot flame
indicates dust and dirt in the pilot assembly. There is a small pilot
air inlet hole about two inches from where the pilot flame comes out
of the pilot assembly (see Figure 41). With the unit off, lightly blow
air through the air inlet hole. You may blow through a drinking straw
if compressed air is not available.

Figure 40 - Injector Holder On Outlet Burner Tube

Burner
Tube

Injector Holder (May
Be Brass or Aluminum
Depending on Model)

Primary Air Inlet Holes
(Shape of Holes May
Vary by Model)

Figure 41 - Pilot Inlet Air Hole

Burner
Tube

Pilot Assembly

Pilot Air
Inlet Hole

Ports/Slots

Advertising
This manual is related to the following products: