AREA REQUIREMENTS

U

Un

niittss C

Ce

errttiiffiie

ed

d ffo

orr IIn

nd

do

oo

orr U

Usse

e -- ((b

bllaacckk o

ou

utte

err ccaab

biin

ne

ett))

MUST BE INSTALLED IN AN AREA PROTECTED FROM THE ELEMENTS, SUCH AS WIND, RAIN, WATER (SPRAY OR
DRIP).
1. Place unit so the front side will be completely unobstructed to provide proper air flow. The unit may be closed in

on the top and three sides, but the front M

MU

US

ST

T B

BE

E unobstructed for air circulation and proper operation.

Installation should be such that the cabinet can be moved for servicing if necessary.

2. Unit should be in a well ventilated area. Best results are obtained at temperatures between 65

0

F (18

0

C) and 80

0

F

(27

0

C) for built-in products and 65

0

F (18

0

C) and 90

0

F (32

0

C) for freestanding products.

3. Provisions for electricity and water connection should be determined before placing unit in proper place.

U

Un

niittss C

Ce

errttiiffiie

ed

d ffo

orr O

Ou

uttd

do

oo

orr U

Usse

e -- ((ssttaaiin

nlle

essss sstte

ee

ell o

ou

utte

err ccaab

biin

ne

ett))

1. Place unit so the front side will be completely unobstructed to provide proper air flow. The unit may be closed in

on the top and three sides, but the front M

MU

US

ST

T B

BE

E unobstructed for air circulation and proper operation.

Installation should be such that the cabinet can be moved for servicing if necessary.

2. Unit should be in a well ventilated area with temperature above 45

0

F (7.2

0

C) and below 110

0

F (43

0

C). Best results

are obtained at temperatures between 60

0

F (16

0

C) and 100

0

F (38

0

C).

3. Provisions for electricity and water connection should be determined before placing unit in proper place.
4. For best performance, outdoor units should be installed away from direct sunlight or under a counter or shelter.

GENERAL INFORMATION

U

Un

np

paacckk

1. Remove banding from bottom of carton. Lift carton up and off of the unit.
2. Remove all tape and packaging material from the outside and inside of the cabinet.
3. Keep all carton packaging until your unit has been thoroughly inspected and found to be in good condition.

LEG LEVELER INSTALLATION

R

Re

eaad

d B

Be

effo

orre

e IIn

nssttaalllliin

ng

g LLe

eg

g LLe

evve

elle

errss

W

WA

AR

RN

NIIN

NG

G:: Do not lay unit on top, side, back, or front. If unit is accidentally laid

in any position other than right side up, then the unit must remain in the right side
up position for at least 24 hours before plugging the unit in.

1. Tip unit backwards so there is one foot of clearance on front of the unit. Have

someone to assist you in tilting the unit to prevent it from falling on you while
installing the leg levelers.

2. Screw front two (2) leg levelers into the weldnuts. Leg levelers should be

screwed in unit snug.

3. Repeat steps 1 & 2 with the exception of tipping the unit forwards to screw in

the back two leg levelers.

4. The leg levelers are now installed.
5. The unit should be level from front to back and side to side. If floor conditions

do not allow the unit to sit level, adjust the leg leveler by turning the required
leg leveler counter-clockwise to increase the height and clockwise to reduce
the height.

LLe

eg

g LLe

evve

elle

err

((4

4)) p

pe

err u

un

niitt

W

We

elld

dn

nu

utt

((E

Eaacch

h b

bo

otttto

om

m

cco

orrn

ne

err o

off u

un

niitt))