PARAMETER

VALUE

DESCRIPTION

0 – Inactive, normal state

do<num>

0, 1

1 – Active, triggered state

return

<return page>

Redirect to the page <return page> after the parameter is

assigned. The <return page> can be a full URL path or relative

path according to the current path. If you omit this parameter, it

will redirect to an empty page.

Example: Drive the digital output 1 to triggered state and redirect to an empty page.

http://myserver/cgi-bin/dido/setdo.cgi?do1=1

Query Status of the Digital Input

Note: This request requires Viewer privileges.

Method: GET/POST

Syntax:

http://<servername>/cgi-bin/dido/getdi.cgi?[di0][&di1][&di2][&di3]

If no parameter is specified, all of the digital input statuses will be returned.

Return:

HTTP/1.0 200 OK\r\n

Content-Type: text/plain\r\n

Content-Length: <length>\r\n

\r\n

[di0=<state>]\r\n

[di1=<state>]\r\n

[di2=<state>]\r\n

[di3=<state>]\r\n

where <state> can be 0 or 1.

Example: Query the status of digital input 1.