2 single flush sla – slf – Viking SLAL User Manual

Page 24

Advertising
background image

fIGURE 84

fIGURE 82

8.01

8.02

2.01

fIGURE 83

8.01

8.02

8.04

8.06

8.08

8.09
8.17
8.18

8.19

8.20

8.16

8.05

8.03

fIGURE 81

8.04

8.03

fIGURE 78

3.01

7.03

4.07

fIGURE 77

sla-f

slG

5.15

fIGURE 80

fIGURE 79

8.06 / 8.07

8.06

SECTION TSM 288

ISSUE

A

PAGE 24 OF 36

• Install the l-cup (8.01) and the rotary face (8.02) into the rotor

(2.01)

The seals are now assembled.
For rotor and head installation see pump assembly section

5.2 sINGlE flUsH sla – slf

• Install the O-ring (8.04) onto the static seal (8.03) and then

install the static seal into the casing – make sure that the

location slots line up with the pins in the seal housing

• Install the slinger (5.15)

NOTE: the slinger has raised sections on the internal diameter,

which press onto the shaft
• Install the guard (7.03) and casing (3.01) and secure with

screws (4.07) (See section 6.2 for torque settings)

• Install the O-ring (8.06) into the seal housing and then install

the seal housing (8.07) into the casing

• making sure that the location recesses line up with the seal

washers (8.07)