SECTION TSM 288

ISSUE

A

PAGE 3 OF 36

Source

of Hazards

Potential

Hazards

Frequency

of Hazards

Recommended

Measures

Unvented

Cavities

Build up of explosive gas

Very Rare

Ensure that pump is totally

filled. Consider mounting

ports vertically.

Casing /

Rotors /

Head

Unintended mechanical

contact

Rare

Ensure that operating

pressures are not

exceeded. Ensure that

sufficient NPSH to prevent

cavitation. Service Plan.

Pump

External

Surfaces

Excess temperature.

Electrostatic charging

Rare

User must ensure

temperature limits. Do not

overfill gearboxes with

lubricant. Provide a ground

contact for pump.

Service plan.

Cover

O-Ring

Pump liquid leakage.

Build up of explosive gas

Very Rare

Check selection of

elastomers are suitable for

application. Ensure cover

retaining nuts are tight.

Service plan.

Pump

Casing / Cover

Pump liquid leakage.

Build up of explosive gas

Very Rare

Stainless Steel.

Corrosion Resistant.

Shaft Seals

Excessive temperature.

Unintended mechanical

contact. Leakage. Build

up of explosive gas

Rare

Selection of seal system

must be suitable for

application. Manual.

Service plan. Seals must

never run dry.

Auxiliary

System for

Shaft

Sealing

Pump liquid leakage.

Build up of explosive gas

Rare

Selection of auxiliary seal

system must be suitable

for application. Seals must

never run dry.

Rotation

Direction

Test

Excess Temperature

Very Rare

If flushed seals are

installed, ensure that

flush is applied to seal

assemblies. Only allow

pump to run for minimum

period - just a few seconds.

Closed

Valve

Condition

Excess Temperature.

Excess Pressure.

Mechanical Contact

Rare

Can cause excessive

pressure, heat and

mechanical contact.

Manual.

Shaft

Random induced current

Very Rare

Provide a ground

contact for pump.

Mechanical

Shaft

Coupling

(Torque

Protection)

Temperature from

friction. Sparks from

break up of shear pins.

Electrostatic charging

Rare

Coupling selection must

suit application.

Provide ground

contact for pump.

Mechanical

Shaft

Coupling

(Standard)

Break up of spider.

Unintended

mechanical contact.

Electrostatic charging

Rare

Coupling selection must

suit application. Service

plan. Provide ground

contact for pump.

NOTE

for a feature to be suitable for an application, the

feature must be fit for its designated purpose and also

suitable for the environment where it is to be installed.

1.1 RIsK assEssMENT RElaTING

TO THE UsE Of VIKING PUMP

sl sERIEs ROTaRY lObE

PUMPs aNd PUMP UNITs IN

POTENTIallY EXPlOsIVE

aTMOsPHEREs

2.0 INTROdUCTION
2.1 GENERal

SL Series rotary lobe pumps are manufactured by Johnson

Pump (UK) Ltd. , a subsidiary of Viking Pump Co., (a unit of the

IDEX Corporation).
This manual includes all the necessary information for SL

Series pumps and should be read prior to beginning installation,

operation, or maintenance.
Should you require any additional information regarding the

SL Series pumps contact Viking Pump or their local authorized

distributor, refer to section 2.2.
When asking for assistance please provide the pump model

and serial number. This information can be obtained from the

pump nameplate which is located on the side of the bearing

housing, refer to section 2.7.
Should the nameplate be unreadable or missing the serial

number is also stamped on either side of the casing refer to

section 2.7.
If the system or product characteristics are to be changed from

the original application for which the pump was selected, or

their authorized distributor should be consulted to ensure the

pump is suitable for the new application.

2.2 VIKING PUMP dIsTRIbUTORs

Viking Pump distributes its products internationally via a network

of authorized distributors. Throughout this manual where

reference is made to Viking Pump, service and assistance will

also be provided by any Viking Pump authorized distributor for

SL Series pumps.

2.3 RECEIPTs aNd sTORaGE

Upon receipt of the pump, immediately examine it for any signs

of visible damage. If any damage is noted, contact Viking

Pump or your Viking Pump distributor and clearly mark upon

the carriers’ paperwork that the goods have been received in a

damaged condition, with a brief description of damage.
If the pump is not required for immediate installation then it

should be stored in a clean, dry environment. It is recommended

that storage temperature should be between –10°C and 40°C

(14°F and 105°F).
Additionally, if the pump is not intended for installation or use

within 18 months or more then refer to Viking Pump or the Viking

Pump authorized distributor for storage recommendations.

2.4 ClEaNING

The SL Series pump range is suitable for manual cleaning and

in-line cleaning refer to section 3.4.1.
The mechanical seals are mounted directly behind the rotor

and are designed and to minimize product entrapment and

maximize the effects of cleaning.
This strategic positioning of the mechanical seals, combined

with their ease of access provides an arrangement that can be

more effectively cleaned by both manual and in-line cleaning

procedures.
Whenever the pump head is dismantled, and at regular intervals

as determined by local operating conditions and verified

cleaning procedures, including installations where the pump

is only operated using n-line cleaning procedures, the areas

behind the rotor case adjacent to the mechanical seals and the