- 6 -

ambient-air intake and hot-air exhaust must not be short-circulated. A piece of
wood may be used to separate them.

• Cut a rectangular inside opening at the rear of the cabinet with the 1/4”

clearance inwards to the width and height of the cooling unit. By not going
through, leave 1/2” lip inside at the wall to place the gaskets (see Fig. 2.1 &
2.2).

• If top exhaust installation, cut another rectangular opening at the top of the

cabinet to the length and width of the top exhaust (see Fig.2.1 & 2.3).

• Install 2 pieces of ¼” ID wood thread inserts at the ceiling (see Fig.2.1 & 2.4).

• Place the gaskets (1/2” foam tape) on the gasket lips (see Fig 2.1 & 2.5).

• If top exhaust installation, place another gaskets along the top exhaust at the

top of the cooling unit (see Fig.2.6).

• Move the cooling unit towards the mounting sides and push to press the

gaskets.

• Use 2 mounting brackets and ¼” screws with 7/16” wrench to secure the

cooling unit (see Fig 2.7 & 2.8).

• If top exhaust, install another top exhaust grille at the top of the cabinet (see

Fig 2.9).

• Plug the cooling unit in the cabinet receptacle.

• Plug the wine cabinet.