1. The spa must be permanently con-

nected (hardwired) to the power sup-
ply. No extension cords or plug-type
connections are to be used in con-
junction with the operation of the
spa. Failure to supply power to the
spa that is not in accordance with
these instructions could create a
potential health hazard and will void
both the manufacturer’s warranty
and the independent testing agency
listing.

2. The National Electrical Code (NEC)

requires that the power supply to this
spa must be a dedicated,ground fault
circuit (GFCI) protected circuit with no
other appliances or lights sharing
power on this circuit.

3. Refer to the wiring diagram posted

inside the electrical equipment door
to determine the current, voltage,
and wire size requirements for your
spa.

4. THHN type wire is recommended.The

wire size for the distance of the wire
run must conform to NEC and local
electrical codes.

5. To ensure proper connections use

copper conductors only.
DO NOT USE ALUMINUM WIRE.

6. The spas’ power terminal strip is

located within the electrical control
box.

7. Feed supply conductors through

power supply inlets provided on the
spa and install into the control box.
Modifications to the electrical
equipment box are not permitted.
Drilling holes in the electrical con-
trol box to provide access for wires
in areas other than those provided
for will void the manufacturer’s war-
ranty and the independent testing
agency listing.

8. Connect wires to terminal block (TBI)

color for color. All wires must be con-
nected or damage may result.
TIGHTEN SECURELY!

ALL WIRING TO THE SPA SHOULD BE IN ACCORDANCE WITH ALL

LOCAL AND NATIONAL ELECTRICAL CODES. ALL WIRING SHOULD BE

PERFORMED BY A LICENSED ELECTRICIAN KNOWLEDGEABLE IN THE

OPERATION AND WIRING OF A GFCI PROTECTED SYSTEM.