Vinotemp WINEMATE WM1500 SSW User Manual

Page 13

Advertising
background image

g. Low

voltage

h. Operating 60 Hz unit at 50Hz
i. Sealed

system

problem


j.

Undercharge or overcharge

g. Check power supply
h. Use proper 60 Hz
i. Call service for checking loss of

refrigerant or restrictions

j. Call service to add or remove

refrigerant

7. House circuit tripping

a. Incorrect fuse or breaker
b. Incorrect

wirings

c. Failed

components

a. Check for proper fuse or breaker
b. Check for wirings and connections
c. Call service

8. Noisy operation

a. Mounting area not firm
b. Loose

parts



c. Compressor overloaded due to high

ambient temperatures or airflow
restriction

d. Malfunctioning

components

a. Add support to improve installation
b. Check fan blades, bearings, cabinet

washers, tubing contact and loose
screws.

c. Check for airflow blockage


d. Call service for checking Internal

loose, inadequate lubrication and
incorrect wirings


























- 12 -