Vinotemp WINEMATE WM1500 SSW User Manual

Page 7

Advertising
background image

The condensing unit and unit cooler are connected by a liquid line and an
insulated suction line that are supplied by the installer. These lines must be
properly sized for the distance between the two units. After the units and the lines
are installed, the system must be pressure tested. If no leaks are found,
evacuate and charge system with R134A. Refrigerant amount will vary
depending on the length of line set.

3. Electrical Wiring

• We strongly recommend against the use of an extension cord. However, if

you still select to use an extension cord, it is absolutely necessary that it is
a UL LISTED 3-wire grounding type appliance extension cord. The
marked rating of the extension cord should be 115 V, 20 A. or equivalent
and not greater than 15ft in length.




1500& 2500SSW Electrical Wiring Diagram


- 6 -

Advertising
This manual is related to the following products: