Handset Level Adjustments

Strata CIX DP5000-series Telephone UG 02/08

81

Handset Level Adjustments

Change the Carbon setting if a Carbon type handset or headset is connected to the
handset jack. This feature is not available on the Single Line Telephone (SLT).

³ To change the Carbon Setting

1. Press

3+6+9+Hold

(simultaneously).

2. Press

Spdial

.

3. Press

FB1

to toggle On/Off.

FB1, LED On: Carbon type handset

FB1, LED Off: DP5000 ECM handset (default)

4. Press

Hold

to set the option.

5. Go off-hook, then on-hook to exit the program mode.

³

To adjust the Handset Transmit Level for DP5000-series telephones
1. Press

3

+

6

+

9

+

Hold

(simultaneously).

2. Press

Redial

.

3. Set the level using FB1, FB2 and FB3.

For Single Line Telephone, use 1,2,3 and Msg. See table below.

4. Press

Hold

to set the option.

5. Go Off-hook, then on-hook to exit the program mode.

Handset Transmit Level

Transmit

Level

FB1

FB2

FB3

SLT

Press 1 and Msg

Press 2 and Msg

Press 3 and Msg

Max. (louder)

ON

ON

ON

OFF

ON

ON

ON

OFF

ON

Default

OFF

OFF

ON

ON

ON

OFF

OFF

ON

OFF

ON

OFF

OFF

Min. (softer)

OFF

OFF

OFF