Recharging power city’s battery, 3 lamp replacement – Vector Power City VEC029AC User Manual

Page 14

Advertising
background image

14

6.3

LAMP REPLACEMENT

The only lamp is in the Lantern Assembly. For any maintenance of the lamp, you will need a

small Phillips screwdriver and a soft clean cloth. Replacement bulbs are available from Vector

Technical Support Department; call (954) 584-4446 for replacements. Warning Fluorescent

bulbs are fragile, be careful while handling.

NOTE

: DO NOT use any metal tools to remove or replace bulb. See Figure 10.

FIGURE 11

1. Make sure the Lantern is turned off.

2. Remove the Lantern Assembly from the main unit.

3. Remove the Phillips type screw (turn counter-clockwise).

4. Lift the lens upward and off and set it aside.

5. Using a clean cloth, rotate the top of the bulb away from the reflector.

6. Pull the burned out bulb upwards and towards the front of the Lantern Assembly.

This will remove it.

7. Replace with a new fluorescent 9 watt bulb.

8. Snap the lens into place (bottom tab first) and replace the two screws.

9. Carefully turn the screw clockwise to tighten. DO NOT OVER TIGHTEN screw.

10. Dispose of burned out bulb in a responsible manner. Follow local ordinances for disposal.

7.

RECHARGING POWER CITY’S BATTERY

Lead-acid batteries require maintenance to maintain a full charge and to ensure good battery

life. All lead-acid batteries suffer from self-discharge over time and more rapidly when they are

at higher temperatures. Therefore, these types of batteries need periodic charging to replace

energy lost through self-discharge. When Power City is not in use Vector recommends that the

batteries be recharged at least every 60 days.
All batteries must be recharged as soon as possible after each use. If a battery is allowed to

remain in a discharged state, battery life will be reduced.
NOTE:

Recharging battery after each use will prolong battery life; frequent heavy discharges

between recharges will reduce battery life. Overcharging will reduce battery life.

The battery can be recharged using several different methods. The time required to fully

recharge these batteries depends on the charge status of the battery after the use of DC

appliances, Inverter and Compressor.
NOTE:

Pressing the battery status push-button turns on the battery status display on the

main unit

Check the battery charge level by pressing the Charge Status Button. The LED Charge Status

display will indicate the level of charge of the battery.

LANTERN

LENS

LENS

RETAINING

SCREW

FLUORESCENT

LAMP

SPRING CLIP

BOTTOM

LENS TAB

Advertising