15

7.1

AC RECHARGE

AC Recharge requires the use of the supplied AC/DC Adapter. The adapter must be powered

from 110 volt AC, 60 Hz North American standard household AC receptacles.

The Battery Status Display will automatically activate during AC recharge. As recharge

progresses, the red LEDs will light one by one. Charge the Power City until the Battery Status

Display lights the green FULL LED. Continue to recharge for one to two hours, and then discon-

nect the AC Recharger. AC recharge is an automatic float and taper charge and The AC

Recharger can be left connected to the Main Unit for long periods. See Figure 2 for AC Re-

charge connection to the Main Unit. Refer to Section 7.2 for Recharge Method.

Make sure that the inverter, compressor and lamp ON/OFF Switches are in off position during

AC recharging.

7.2

DC RECHARGE

Power City is supplied with two accessory cables. One cable is a black Inverter Power Cable

with an attached thinner Lantern Extension Cord. It is to power the inverter when it is used with

another accessory socket in a vehicle or boat. An attached thinner wire is dubbed Lantern

Extension Cord" and it is used to power the Lantern. The DC Recharge Cable has red and black

wire and it mates with the Inverter Power Cable to make a DC to DC cable.

After recharge, the accessory cables are stored in their own Cable Storage Hatch in the Main Unit.

Recharging the Main Unit’s internal battery from an external DC power source requires the use

of the DC Recharge Cable and the Inverter Power Cable. See Figure 11. The Lantern Extension

Cord can be connected to the Lantern to simultaneously recharge the Main Unit and power the

Lantern (not shown).

FIGURE 12

Make sure Safety ON/OFF Switch, inverter, and compressor switches are in the OFF position

during DC recharging.

Unlike the AC Recharge method, DC Recharge does not automatically activate the Battery

Status Display. To check the battery status, press the Battery Status Display Push-button. If the

Jump Starter's battery is fully discharged, it is recommended that the host vehicle or boat's

engine being used for recharging be left operating while the unit is being charged using the 12

volt DC/DC method.

WARNING:

DO NOT recharge main unit for more than 8 hours maximum using 12 volt DC

method. do not charge lantern for more than five hours using the dc recharge method.

1. Remove both power cables from the Cable Storage Hatch.

2. Insert the red DC Recharge Cable's rectangular connector flat pins into the black rectangular

connector on the Inverter Power Cable.

3. Insert black DC Plug on the Inverter Power Cable into a DC Accessory socket on the

Main Unit.

4. Plug the red DC Plug into an accessory socket in a vehicle, power supply or other 12 VOLT

DC source.