Hinge adjustment – Viking AF/AR User Manual

Page 23

Advertising
background image

46

45

Remove four side screws and remove unit top.

Loosen the four hinge screws. Adjust door.

Retighten four hinge screws.

Replace unit top. Replace four side screws.

Attach one 2x4 to wall stud (refer to dimensions page

for exact location).

If needed, depending on cabinet and depth,

attach second 2x4 to first 2x4.

2

1

5

Front of unit

2

1

3

6

1

2

7

8a

Wall

2 x 4

Refrigerator

8b

Wall

2 x 4

Refrigerator

Hinge Adjustment

9

3”

3”

3”

10a

Plug in power cord to verify operation.

Note: Make sure power switch and showroom switch

are in the “On” Position.

Place unit within 3” of being flush with cabinets.

Note: To avoid cabinet damage, place cardboard

between cabinets and unit. When moving unit, do not

crimp, kink or crush water supply line.

10b

11

Carefully move unit until semi flush with cabinet

(depending on unit).

Pull supply tubing forward under unit.

Note: DO NOT use plastic water lines.

12

13

Flush water line by running two quarts of water

into a bucket. Turn water off

Connect supply tube to water valve using

a 1/2” wrench. Note: DO NOT overtighten.

Advertising