Pressure relief procedure, Warning – Wagner HIGH PERFORMANCE AIRLESS SPRAYER User Manual

Page 8

Advertising
background image

8

Pressure Relief Procedure

Follow this procedure after the unit is assembled and before any operation which involves the spray gun such as
changing tips or accessories, or cleaning and maintenance.

1. Make sure PRESSURE CONTROL KNOB is at its lowest

setting (counterclockwise).

2. Turn PRIMING KNOB to PRIME A position.

3. Trigger gun to remove any pressure which may still be

in the hose.

place. NEVER trigger gun unless tip is completely turned
to the spray or unclog position. ALWAYS engage trigger
lock before removing, replacing or cleaning tip.

Injection hazard possible. Do
not spray without tip guard in

WARNING

4. Lock gun trigger in the Off position.

Pressure Control

Knob

Prime A

Spray B

Knob

Trigger Lock

Advertising