Planning Information

Integrated Gas Multi-Function Cooktop

M O D E L I M 1 5 / S

Dimensions in parentheses are in
millimeters unless otherwise specified.

5

For the integrated multi-function cooktop,

the gas service may be supplied through the
floor. Refer to the illustration on page 4 for
placement of electrical and gas supply.

The Wolf multi-function cooktop is designed

to operate on natural gas at 5" (12.5 mb) WC
(water column) pressure or LP gas at 10" (25
mb) WC pressure. The minimum line pressure
for natural gas is 7" (17.5 mb) WC and 11"
(27.4 mb) WC for LP gas. The maximum gas
supply pressure to the regulator should never
exceed 14" (34.9 mb) WC; .5 psi (3.5 kPa). It is
supplied with a

1

/

2

" NPT male gas connection

at the right rear bottom corner of the cooktop.
The male connector exits the unit straight down
and you are supplied with a regulator with two
female connectors.

You must follow all National Electrical Code

and gas regulations. In addition, be aware of
local codes and ordinances when installing your
services.

Wolf gas cooktops using natural gas

function up to an altitude of 8,000' (2438 m)
without any adjustment. Natural gas installa-
tions from 8,000' (2438 m) to 10,000' (3048 m)
need the high altitude conversion kit. LP gas
installations will operate up to 10,000' (3048 m)
without adjustment.

Refer to the installation instructions

shipped with each Wolf product for detailed
specifications.

I N S T A L L A T I O N N O T E S

Refer to the illustrations and specifications

for overall dimensions, cut-out dimensions and
installation specifics.

Wolf recommends using 33" (838) wide

cabinets for installation of two integrated
modules side by side. An 18" (457) wide
cabinet is recommended for installation of a
single integrated cooktop module.

IMPORTANT NOTE: Review specific installation
instructions for product to product capabilities

When multiple cooktops or modules are

installed side by side, refer to the countertop
cut-out dimensions on page 6.

A Wolf downdraft system, Cooktop or

Pro ventilation hood is recommended. When
installing a ventilation hood, refer to the specific
requirements of the hood for the minimum
dimension to countertop. Also refer to the
ventilation recommendation charts in the
cooktop or Pro ventilation sections of our
website, wolfappliance.com.

The Wolf integrated gas multi-function

cooktop requires a separate 120 V AC, 60 Hz
power supply. The service should have its own
15 amp circuit breaker and a grounded 3-prong
receptacle should be located within the reach of
the 6' (1.8 m) power cord. Locate electrical
within the shaded area shown in the illustration
on page 4.

IMPORTANT NOTE: A ground fault circuit
interrupter (GFCI) is not recommended and may
cause interruption of operation.

This cooktop is intended for indoor use only.