White Rodgers 50A62-820 User Manual

Page 5

Advertising
background image

5

50A62

TERMINAL

TERMINAL

TYPE

SYSTEM COMPONENT

CONNECTION

TYPICAL SYSTEM WIRING TABLE

* maximum recommended flame probe wire length is 36 inches.

W

G

R

Y

C

MV (2 terminals)

RO1

RO2

PS

PS

GND

HL

(unused terminal)

IND

IGN

GND

GND

(unused 2 terminals)

COOL

HEAT

M1

M2

FAN

LINE

XFMR

CIR N

LINE N

XFMR N

HUM

EAC (optional)

HUM N

EAC N (optional)

TR

TH

FP

captive screw

captive screw

captive screw

captive screw

captive screw

9-pin
connector
& harness

6-pin
connector
& harness

spade terminal

spade terminal

spade terminal

spade terminal

spade terminal

spade terminal

spade terminal

spade terminal

spade terminal

spade terminal

spade terminal

spade terminal

spade terminal

spade terminal

spade terminal

spade terminal

spade terminal

low voltage thermostat W terminal (or equivalent)

low voltage thermostat G terminal (or equivalent)

low voltage thermostat R terminal (or equivalent)

low voltage thermostat Y terminal (or equivalent)

2nd wire from Y terminal goes to 24 VAC HOT side of

compressor contactor coil

24 VAC COMMON side of compressor contactor coil

gas valve (both gas solenoids are connected in parallel)

rollout switch OUTPUT

rollout switch INPUT

pressure switch INPUT

pressure switch OUTPUT

MUST BE RELIABLY GROUNDED TO CHASSIS

high limit switch input

inducer HOT side

ignitor HOT side

inducer NEUTRAL side

ignitor NEUTRAL side

circulator blower COOL SPEED terminal

circulator blower HEAT SPEED terminal

unused circulator blower terminal

unused circulator blower terminal

circulator blower FAN SPEED terminal

input voltage (120 VAC) HOT side

24 VAC transformer line voltage HOT side

circulator blower NEUTRAL terminal

input voltage (120 VAC) NEUTRAL side

24 VAC transformer line voltage NEUTRAL side

humidifier HOT side

electronic air cleaner HOT side

humidifier NEUTRAL side

electronic air cleaner NEUTRAL side

24 VAC transformer (low voltage COMMON side)

24 VAC transformer (low voltage HIGH side)

flame sensor port*