Gas supply – weber Summit Gas Grill S-460 User Manual

Page 32

Advertising
background image

VEntiLation
m warning: Ventillation holes must be provided in the structure

at the top and bottom to provide ventilation in the event of a
gas leak.

Ventilation holes can be located in a low visibility area and should be protected by
screening material to prevent rodents and insects from entering the structure. Air holes will
also help dry moisture.

Note: These drawings are only a reference.

Cross ventilation must be incorporated in the supporting structure. We recommend a
minimum of 100 square inches (254 square cm )of venting per side.

Vents should be on two sides of the structure.

The above drawings are for reference only.

Location of the vents should be from the center, outward.

Locate the vents at both the bottom of the structure and at the top of the structure.

The bottom vents should be as close to ground level as possible. Make sure the vent
area is not blocked by interior supports of the structure.

We recommend vents with screens.

Access doors to the structure are not considered vents.

Clean the vents periodically.

m dangEr: failure to follow recommended minimum venting

instructions can cause gas to collect in the structure in the
event of a gas leak. this may result in a fire or an explosion
which can cause serious bodily injury or death, and damage to
property.

Gas sUPPlY

©2009 The following trademarks are registered in the name of Weber-Stephen Products Co., an Illinois corporation, located at 200 East Daniels Road, Palatine, Illinois 60067 U.S.A.

Australia; Smokey Joe, Weber, Kettle Silhouette , Genesis, Austria; Kettle Silhouette , Smokey Joe, Weber, Benelux; Kettle Silhouette , Smokey Joe, Weber, Compact Grill Configura-

tion, Botswana; Weber, Canada; Smokey Joe, Genesis, China; Kettle Silhouette , Denmark; Kettle Silhouette , Smokey Joe, Weber, Finland; Smokey Joe, France; Kettle Silhouette ,

Smokey Joe, Weber, One-Touch, Germany; Smokey Joe, Weber, One-Touch, Greece; Smokey Joe, Ireland; Kettle Silhouette , Smokey Joe, Italy; Smokey Joe, Weber, Japan; Smokey

Joe, Weber, Korea; Smokey Joe, Weber, New Zealand; Weber, Smokey Joe, Nigeria; Weber, Norway; Smokey Joe, Weber, Portugal; Weber, South Africa: Smokey Joe, Weber, Kettle

Configuration, Spain; Smokey Joe, Weber, Sweden; Kettle Silhouette , Smokey Joe, Switzerland; Kettle Silhouette , Smokey Joe, Weber, United Kingdom; Smokey Joe, Weber, Weber

One-Touch, U.S.A..; Kettle Configuration, Kettle Silhouette , Smokey Joe, Weber, One-Touch, Firespice, Go-Anywhere, U.S.A.;Kettle Configuration, Kettle Silhouette, Genesis, Flavorizer,

Crossover, Flamgo, Performer, Rapidfire, Tuck ‘N Carry, Jumbo Joe, Bar-B-Kettle, Master-Touch, Spirit, Grill Out, Summit, Platinum, 1-800-Grill-Out, Ranch, Matchless Flame, Zimbabwe;

Weber, Kettle Configuration, Kettle Silhouette .

m attEntion: this product has been safety tested and is only certified for use in a specific country. refer to country designation

located on outer carton.

These parts may be gas carrying or gas burning components. Please contact Weber-Stephen Products Co., Customer Service Department for genuine Weber-
Stephen Products Co. replacement part(s) information.

m warning: do not attempt to make any repair to gas carrying, gas burning, igniter components or structural components without

contacting weber-Stephen Products Co., Customer Service department. Your actions, if you fail to follow this Product warning,
may cause a fire, an explosion, or structural failure resulting in serious personal injury or death as well as damage to property.

WEBER-STEPHEN PRODUCTS CO.