WhisperKool 17-1103 User Manual

Page 28

Advertising
background image

Temperature Data from Testing

Temperature \ Test

(time)

First

(after 5 mins)

Second

(after 8 hrs)

Third

(after 24 hours)

Inlet Air

Outlet Air

E

v

a

pora

tor

(F

ront

) Si

de

Differential

(Inlet – Outlet = _; ideally 10°F-15°F)

Inlet Air

(ideally <90°F)

Outlet Air

(ideally <120°F)

C

onde

ns

e

r

(

B

a

c

k

)

Si

de

Differential

(Inlet – Outlet = _; ideally around 30°F)

-26-

Temperature Testing Locations

Inlet Air – Evaporator (Front) Side

Outlet Air – Evaporator (Front) Side*

Inlet Air – Condenser (Back) Side•

Outlet Air – Condenser (Back) side*

*When measuring outlet air temperature on both sides of the unit (from the
circular fans), hold the thermostat at the outer edges of one of the circular fans.

Third Temperature Test:

10. After the unit has run for 24hours, perform the third and last temperature test.

11. Record information and calculate temperature differential in table below.