This guide is meant to serve as a quick reference for installation of the
WhisperKOOL unit. The remainder of this Owner’s Manual will provide more
detailed information and instructions.

Upon receiving the WhisperKOOL unit:

QUICK START GUIDE

1. Inspect the unit before installation. If damage is found, please contact your

distributor or Vinothèque Customer Service at 1.800.343.9463 ext 799.

2. The unit should remain in an upright position for 24 hours prior to

operation.

3. The unit is designed to gently cool down the temperature of the cellar over

time by cycling cooler and cooler air throughout. Test the unit prior to
installation
. With power off, attach the “by-pass plug” (included in accessory
bag) to the open plug located on the unit, where the PDT thermostat will need
to be installed. Operate unit for twenty minutes. While the unit is running and
working properly, the air discharged from the front should be 10 - 15°F
cooler than the air
in the room. This means that in an environment where
the air is 80°F, the unit will discharge air that is 68°F.

4. The WhisperKOOL unit requires a dedicated 110-volt 20-amp circuit (or 220-volt

depending on the unit). Use a surge protector with the WhisperKOOL unit. Do not
use a GFI
(Ground Fault Interrupter) line.

5. For your convenience, the Whisperkool unit has two power sockets, one on the

side of the unit and the other on the back. Both sockets come covered. Remove
the cover from

only

the desired power socket in order to plug the unit in.

6. After testing, remove the “by-pass plug,” mount unit to desired location, and

install the PDT thermostat into the plug. There is a five (5) minute delay on
initial start up of the unit.

7. In areas of high humidity, put the condensate evaporator switch to the

“ON” position. It is also necessary to install the drain line to remove excess
condensation from the unit.

8. The WhisperKOOL unit is intended for use in properly designed and

constructed wine cellars. Hire a professional wine storage consultant with a
valid contractor’s license to build your wine cellar. Refer to the “How to Build a
Wine Cellar” video available on the Vinothèque website at www.vinotheque.com.

Install the foam strips along the inside edge of the unit’s flange to assure a
proper seal against the wall.

Never try to open the WhisperKool unit, repair it yourself, or use a
service company without Vinothèque’s authorization. This will void your
warranty.

If you encounter a problem with your WhisperKool unit, please refer to the
Troubleshooting Checklist on pages 23-26. If you have any further questions,
concerns, or need assistance, please contact Vinothèque Customer Service at
1.800.343.9463 ext. 799. Please be sure all testing has been completed prior to
contacting Customer Service. Please have your results ready for your
representative.