Installation Instructions for

Heating & Air Conditioning

1F78H

5/2 Day Programmable Thermostat

CONTENTS

Preparations .................................................. 1

Thermostat Details ........................................ 1

Removing Old Thermostat ............................ 1

Mounting and Wiring ..................................... 2

Check Thermostat Operation ........................ 3

Configuration Menu ....................................... 4

Programming your Thermostat ..................... 5

Specifications ................................................ 7

Troubleshooting ............................................ 8

PREPARATIONS

THERMOSTAT DETAILS

REMOVING OLD THERMOSTAT

Before removing wires from old thermostat’s switching subbase,
label each wire with the terminal designation it was removed from.

1. Remove Old Thermostat: A standard heat/cool thermostat

consists of three basic parts:

a. The cover, which may be either a snap-on or hinge type.

b. The base, which is removed by loosening all captive screws.

c. The switching subbase, which is removed by unscrewing

the mounting screws that hold it on the wall or adaptor plate.

2. Shut off electricity at the main fuse box until installation is

complete. Ensure that electrical power is disconnected.

3. Remove the front cover of the old thermostat. With wires still

attached, remove wall plate from the wall. If the old thermostat
has a wall mounting plate, remove the thermostat and the wall
mounting plate as an assembly.

4. Identify each wire attached to the old thermostat.

5. Disconnect the wires from the old thermostat one at a time.

DO NOT LET WIRES FALL BACK INTO THE WALL.

6. Install new thermostat using the following procedures.

To prevent electrical shock and/or equipment damage,
disconnect electrical power to the system at the main
fuse or circuit breaker until installation is complete.

CAUTION

!

Printed in U.S.A.

PART NO. 37-6448A

0247

WHITE-RODGERS
EMERSON ELECTRIC CO.
9797 REAVIS ROAD
ST. LOUIS, MISSOURI 63123-5398
www.white-rodgers.com

Failure to follow and read all instructions carefully
before installing or operating this control could cause
personal injury and/or property damage

Assemble tools required as shown below.

YOUR THERMOSTAT REPLACES

1

2

3

WIRE CUTTER/STRIPPER

Typical System Compatibility Chart

1F78H

Standard Heat Only Gas or Oil Fired Systems (24 volt)*

Yes

Electronic Ignition Heat Only Two Wire Systems (24 volt)*

Yes

Electronic Ignition Heat Only Gas or Oil Fired Systems (24 volt)*

Yes

Standard Heat/Cool Systems (24 volt)*

Yes

Heat/Cool Systems Electric Heat (24 volt)*

Yes

Heat Only Electric Heat Systems (24 volt)*

Yes

Cool Only Systems (24 volt)*

Yes

Heat Pump Systems (No Aux or Emergency Heat)*

Yes

Hot Water Zone Heat Only Systems

No

Hot Water Zone Heat Only (Three Wire) Systems

No

Line Voltage Heating or Baseboard 110/240 Volt Systems

No

Millivolt Systems Floor or Wall Furnaces

No

12 VDC Mobile Home Application

No

Multistage Systems

No

Systems Exceeding 30VAC, 1.5 Amp

No

* Requires common wire for 24VAC at the thermostat

W

RH

B

RC

G

C

O

Y

GAS

ELEC

W904

W905

Figure 1. Thermostat base

Mounting

hole

Mounting

hole

W905

Clip for

Hydronic

System

W904

Clip for

Celsius Display

Electric/Gas

Switch

HAND OR POWER
DRILL WITH 3/16 INCH
DRILL BIT, IF NEEDED

FLAT BLADE SCREWDRIVER

SPIRIT LEVEL OR PLUMB BOB AND LINE OPTIONAL—

THERMOSTAT DOES NOT NEED TO BE LEVEL TO WORK PROPERLY