Program mode quick reference – Watlow MINICHEF 2000 Griddle Applications User Manual

Page 5

Advertising
background image

4

Wa t l o w M

I N I

C

H E F

2 0 0 0

A p p l i c a t i o n 2 0

Program Mode Quick Reference

These are the functions, parameters and values included in the Program Mode for this
application. You must select Application 20 to access them. For menu programming
directions, see the Hardware & Software Setup Guide. The Appendix of that guide
includes a detailed explanation of all parameters and values.

Function

Parameter

Setting

Your Settings

[

M`--]

[

Stpt1] Set point 1

Temp range low

Menu Numbers 1 - 6

Temperature of channel 1.

to temp range high.

[TiNe1] Time 1

Format varies based on

Menu run time.

configuration. Setting at 0
invalidates selected menu.

[

Stpt2] Set point 2

Temp range low
to temp range high.

Auto-tuning Note:

Before auto-tuning Application 20 for zone 1, Set Point 1 of Menu 1 must first be set to
a value that is typical for zone 1. (See the Hardware & Software Setup Guide for infor-
mation on programming menus.) Then set [tHErL] / [tunE1] to [```on]. After you
accept [```on], by pressing “Enter,” the controller will display [`tunE] while auto-
tuning is taking place.

Then you can auto-tune zone 2, by first setting Set Point 1 of Menu 1 to a value that is
typical for zone 2. Then set [tHErL] / [tunE2] to [```on]. After you accept [```on],
the controller will display [`tunE] while auto-tuning is taking place.

The controller will cancel the auto-tuning process if it cannot be completed in 80 min-
utes. You can cancel the auto-tuning process at any time by pressing either key C or key
D and accepting [``Off], by pressing “Enter,” when it appears.