Required power supply:

Single phase: 220-240V AC; 50 Hz
3phase: 380-410V AC; 50 Hz

Maximum connected load:

Single phase: 3.6 kW
3phase: 3.6 kW

Total amps:

Single phase: 16 amps
3phase: 16 amps

7 6 2 m m I N D U C T I O N C O O K T O P S

Required power supply:

Single phase: 220-240V AC; 50 Hz
3phase: 380-410V AC; 50 Hz

Maximum connected load:

Single phase: 7.2 kW
3phase: 3.6 kW

Total amps:

Single phase: 32 amps
3phase: 16 amps

E L E C T R I C A L  

R E Q U I R E M E N T S

Verify that power is disconnected from
the electrical box before proceeding.

9 1 4 m m I N D U C T I O N C O O K T O P S

Required power supply:

Single phase: 220-240V AC; 50 Hz
3phase: 380-410V AC; 50 Hz

Maximum connected load:

Single phase: 11.2 kW
3phase: 4 kW

Total amps:

Single phase: 49 amps
3phase: 18 amps

Refer to the wiring diagram showing the
connections for each lead to the terminal box
on the unit.

N

L1

Single phase wiring diagram

N

L1
L2
L3

3phase wiring diagram