If UCC/EAN-128 is enabled on the RF Terminal reader, all Function 1 codes are transmitted as ]C1. In
addition, should you be reading a 20 digit Shipping Serial Container code, the Mod 10 check digit is also
compared with the computed Mod 10 value to give further assurance of no substitutions. The UCC/EAN-
128 Shipping Serial Container Code is a subset of UCC-128 or EAN-128 adopted for voluntary marking of
shipping boxes with the exact serial number of the box, (used with EDI typically to identify a specific boxes
contents. The code consists of the following format:
Start C
not transmitted
Function Code 1
transmitted
2 Digit Qualifier
transmitted
7 Digit Data Portion
transmitted
1 Digit Mod 10 Check Digit*
transmitted-
1 Digit Modulus 103
not transmitted
Stop Code
not transmitted
*Calculated using 19digits-UPC method
The UCC 128 specification is used extensively by the retail industry. If you have a requirement for a UCC
128 Serial Shipping Container bar code, be sure to follow the specification as closely as possible as many
vendors will impose fines for non-conformance. For more information on UCC 128, contact the Uniform
Code Council at:
Uniform Code Council, Inc.
7887 Washington Village Drive, Suite 300
Dayton, OH 45459
937-435-3870
937-435-7317