Installation, Vertical termination with co-linear flex system – Waterford Appliances E65-NG1 User Manual

Page 14

Advertising
background image

14

Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove

VERTICAL TERMINATION WITH CO-LINEAR FLEX SYSTEM

This appliance is designed to be attached to two
3" (76mm) co-linear aluminium flex running the
full length of the chimney. See the Venting
Arrangements chart below for minimum and
maximum flue lengths. See chart below for
minimum distances from roof. Periodically check
that the vent is unrestricted.

Masonry chimneys may take various contours which the flexible liner will accommodate.
However, keep the flexible liner as straight as possible , avoid unnecessary bending.

The Air Intake pipe must be attached to the inlet air collar of the termination cap.

INSTALLATION

Required Parts:

Part #

Description

945G

45

o

Elbow

946-529

Co-linear DV Vertical
Termination Cap

948-305

3" Flex - 35 ft.

270-944

U27 Dura-Vent Adapter

946-563

Co-Axial to Co-Linear Adapter Kit
which contains the following:
Co-linear Flex Adapter (270-585)
Outer Pipe (946-257)
Inner Pipe Adapter (946-219)

Alternate Approved Caps
980

Vertical Termination Cap

991

High Wind Cap

923GK 3" Co-linear Adapter with flashing

THE APPLIANCE MUST NOT BE

CONNECTED TO A CHIMNEY FLUE

SERVING A SEPARATE SOLID FUEL

BURNING APPLIANCE.

Venting Arrangements - Vertical Terminations

with Co-linear Flex System for both

Residential & Manufactured Homes/

Mobile Homes

The shaded area in the diagram shows the allowable
vertical terminations.
If the vent is ENCLOSED in a chase (min.
size 9" x 9") maintain a 1-1/4" clearance to combustibles.

Straight Vertical Terminations

Advertising
This manual is related to the following products: