Installation, Dv stove horizontal vent kit, Miniumum horizontal termination installations – Waterford Appliances E65-NG1 User Manual

Page 15

Advertising
background image

Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove

15

INSTALLATION

DV STOVE HORIZONTAL VENT KIT

DV 2 ft. Stove Vent Kit (Part # 946-116) and DV 4 ft. Stove Vent Kit (946-216) includes all the parts needed
to install the E65 Direct Vent unit with minimum horizontal and vertical vent dimensions. For
installations that require longer vertical and/or horizontal vents use the Dura-Vent system as shown
onm page 17.

Qty.

Description

1)

1 Rigid Pipe Section (Kit # 946-116: 2 ft. (1.2m) length,

Kit # 946-216: 4 ft. (1.2m) length), 6-1/2" (165mm)
inside diameter

2)

1 Flex Liner, compressed aluminium 2 ply liner, 4" (102mm)

inside diameter

3)

4 spring spacers

4)

1 90 deg. Elbow

5)

1 Adjustable pipe section 13-1/2" to 24" (343mm x 610mm), 2 pcs.

6)

1 Thimble Cover

7)

1 Wall Thimble (2 pcs.)

8)

1 Adapter

9)

1 AstroCap Termination Cap

10)

2 Trim Collars

11)

1 tube of Mill-Pac, high temperature sealant

12)

12 Screws, #8 x 1/2" Self tapping, Stainless Steel

13)

14 Screws, #8 x 1/2" Self tapping, Black

14)

4 Screws #8 x 1-1/2" Drill Point, Black

15)

4 Screws #8 x 1-1/2" Drill Point, Stainless Steel

16)

8 Wood screws #8 x 1"

Required but not included in above Kit:
45

o

Elbow (Part #: 946-214)

Note:
a) Liner sections should be con-

tinuous without any joints or
seams.

b) This is an approved system,

therefore components in this
system must not be substi-
tuted for any other manufac-
turer's products.

MINIUMUM HORIZONTAL TERMINATION INSTALLATIONS

See page 10 for Exterior Vent Termination requirements. The E65 is approved for a minimum horizontal termination with the Regency Riser
Vent Kit. See the diagram on page 13 for minimum and maximum pipe lengths.

When planning your installation, it will be necessary to select the proper length of vent pipe for your particular
requirements. Determine the minimum clearance to combustibles from the rear of the unit to the wall. It is also
important to note the wall thickness. Before cutting the vent hole through the wall ensure that ALL vent and
termination clearances (see page 7) will be met.

NOTE: Ensure compliance with the outside vent terminal location before cutting hole as both dimensions
must be met.

You will require the following components with your new Regency Rear Vent Direct Vent
Freestanding Gas Stove. Please review your product to make sure you have everything you
need. In the event that you are missing any part, contact your dealer. Decorative brass
or chrome trim kits are available from Simpson Dura-Vent for their wall thimbles, as
well as a square wall thimble cover.

Note: These are the minimum pieces required. Other parts may be
required for your particular installation.

Optional Components:
946-204

45

o

Elbow - 6-5/8" Black pipe

and 4" Aluminum Vent

946-205

Vinyl Siding Shield for Riser Vent
Terminal

946-208/P

Vent Guard

940

Square Wall Thimble Cover*

981

Snorkel Termination (36")*

982

Snorkel Termination (14")*

942

Wall Penetration
Heat Shield*

* Simpson Dura-Vent components

Minimum components for a Horizontal Installa-
tion:
640-944

Horizontal Termination Kit which includes:
1 946-201

6-5/8" Dia. x 18" Black Pipe

1 946-207

4" Dia. x 18" Aluminum
Vent

1 946-202

Wall Penetration
Heat Shield
(Wall Thimble) (2 pcs)

1 640-530

Riser Vent Terminal

1 640-545

Decorative Wall Trim (Black)

1 948-128

Tube Mill-Pac Screws

945G*

1 45

o

Elbow

946-219

1 Adapter