Install vent support

1. Apply 1 elastomer gripper to vent support.

2. Intall vent support around vent piping just below

draft hood connector as shown in

Figure 15

. Fasten

support around vent piping with 1 – 1

¹⁄₄" screw.

3. Tighten screw until support does not turn or slide

around vent piping.

Install 5" x 5" x 3" tee

Step 3

Step 4

1. Slide tee over vent piping and attach uncrimped end

to bottom of draft hood connector:
a. Drill 3 holes in tee for

¹⁄₄" sheet metal screws.

Do not

allow drill to

penetrate

vent pipe. Drill

holes carefully in tee and use

only

1

/

4

" screws

to fasten tee

to draft hood connector.
Failure to do so can damage
vent pipe, causing severe
personal injury or substantial
property damage.

b. Seal all seams and screws with approved sealant.

2. Secure bottom cap to tee with duct tape. Slide

elastomer flashing up around vent pipe and tuck
lip into cap’s bottom opening. Seal with approved
sealant.

Follow

vent pipe manufacturer's instructions

to

assemble and seal joints. Sealant recommended by vent
pipe manufacturer must be used as indicated in their
instructions. Vent and combustion air connector piping
must be sealed

gas-tight

to prevent possibility of flue

gas spillage and carbon monoxide emissions, resulting
in severe personal injury or death.

Draft hood
connector

Vent
support

87308

5” x 5” x 3”
Tee

Elastomer
flashing

Draft hood
connector

Bottom cap

87309

Figure 15

Install vent support