removing the sear station

®

burner

To remove the Sear Station Burner

®

, pull the burner tube toward you . This removes it

from the burner tube notch

(7) . Then rotate the tube clockwise (8), taking care to rotate

the burner tube so that the screw at the end of the tube

(9) fits through the notch in the

heat shield opening

(10). When the burner tube is free, remove it from the firebox (11) .

J) To reinstall the manifold assembly, reverse steps G through I .

m Caution: the burner openings (12) must be positioned

properly over the valve orifices (13). make sure the opposite
end of the burner tubes (14) properly align into the slots on
the backside of the cookbox. Check proper assembly before
fastening manifold in place.

m warninG: after reinstalling the gas lines, they should be

leak checked with a soap and water solution before using
the grill. (see “CheCK for Gas leaKs”)

mAINTENANcE

3

1

1

2

2

side burner Grate

side burner Cap

side burner ring & head

igniter electrode

Control Knob

igniter

side burner maintenanCe
m warninG: all gas controls and supply valves should be in

the off position.

Make sure black wire is connected between the igniter and electrode .

Make sure white wire is connected between the igniter and grounding clip .

Spark should be a white/blue color, not yellow .

A) Igniter wire

(1)

B) Ground wire

(2)

C) Burner

(3)